Set generator action on timer event
Set generator action on compare event
Enable MCPWM interrupt for specific event mask
Set which path to bypass in the deadtime submodule
Clear MCPWM interrupt status by mask
Set generator action on brake event
Select the generator for RED block
Select the generator for FED block
Get interrupt status register address
Get MCPWM interrupt status
Enable sync input for timer
Set compare value for comparator
Set peak value for MCPWM timer
Set the sync output signal to one of the timer event
Enable GPIO fault detection
Update MCPWM period immediately
Set MCPWM timer count mode
Execute MCPWM timer start/stop command
Get timer count direction
Disable sync output for MCPWM timer
Update the compare value immediately
Enable to update the compare value upon TEZ event
Enable to update the compare value upon TEP event
Set clock source for dead time submodule
Enable carrier for MCPWM operator
Enable refresh the CBC brake on TEZ event
Use the input sync signal as the output sync signal (i.e. propagate the input sync signal)
Trigger MCPWM timer software sync event
Set sync count value for MCPWM timer
Set sync phase direction for MCPWM timer
Select which GPIO sync input to use
Select which timer sync input to use
Clear timer sync input selection
Invert the GPIO sync input signal
Connect operator and timer by ID
Set generator action on trigger event
Disable continue forced action for generator
Disable non-continue forced action for generator
Set falling edge delay duration
Set rising edge delay duration
Enable to update deadtime on TEZ event
Set prescale for MCPWM carrier source clock
Set duty cycle of MCPWM carrier
Invert the signal after the carrier is applied
Invert the signal before applying the carrier
Set the first pulse width of the carrier
Set fault polarity (i.e. which level is treated as an active fault)
Enable refresh the CBC brake on TEP event
Enable software CBC brake
Enable software OST brake
Enable sync for capture timer
Enable capture on positive edge
Enable capture on negative edge
Set the prescale of the input capture signal
Enable update MCPWM active registers from shadow registers
Flush shadow registers to active registers
Enable to update MCPWM period upon TEZ event
Enable to update MCPWM period upon sync event
Enable to update the compare value upon sync event
Stop updating the compare value
Update operator actions immediately
Enable update actions on TEZ event
Enable update actions on TEP event
Enable update actions on sync event
Set trigger from GPIO (reuse the fault GPIO)
Set trigger from sync event (when the timer/gpio/soft taken the sync signal)
Reset actions for the generator
Trigger non-continue forced action for generator
Set continue force level for generator
Set non-continue force level for generator
Get the deadtime switch topology
Update deadtime immediately
Enable to update deadtime on TEP event
Enable to update deadtime on sync event
Trigger software CBC brake for once
Trigger software OST brake for once
Whether the OST brake is still active
Whether the CBC brake is still active
Set sync phase for capture timer
Set the timer sync source for MCPWM capture timer
Set the GPIO sync source for MCPWM capture timer
Trigger a software sync for capture timer
Trigger the software capture for once
Flush operator shadow registers to active registers