LL_TIM_HALLSENSOR_InitTypeDef::CommutationDelay field
Specifies the compare value to be loaded into the Capture Compare Register. A positive pulse (TRGO event) is generated with a programmable delay every time a change occurs on the Hall inputs. This parameter can be a number between Min_Data = 0x0000 and Max_Data = 0xFFFF. This feature can be modified afterwards using unitary function LL_TIM_OC_SetCompareCH2().