touch_ll_set_slope() function
Set touch sensor charge/discharge speed(currents) for each pad. If the slope is 0, the counter would always be zero. If the slope is 1, the charging and discharging would be slow. The measurement time becomes longer. If the slope is set 7, which is the maximum value, the charging and discharging would be fast. The measurement time becomes shorter.
Arguments
touch_num
Touch pad index.
slope
touch pad charge/discharge speed(currents).
Notes
The higher the charge and discharge current, the greater the immunity of the touch channel, but it will increase the system power consumption.