Local Temperature attribute.
Outdoor Temperature attribute.
The AbsMinHeatSetpointLimit attribute specifies the absolute minimum level that the heating setpoint MAY be set to.
The AbsMaxHeatSetpointLimit attribute specifies the absolute maximum level that the heating setpoint MAY be set to.
The AbsMinCoolSetpointLimit attribute specifies the absolute minimum level that the cooling setpoint MAY be set to.
The AbsMaxCoolSetpointLimit attribute specifies the absolute maximum level that the cooling setpoint MAY be set to.
The PICoolingDemand attribute is 8 bits in length and specifies the level of cooling demanded by the PI (proportional integral) control loop in use by the thermostat (if any), in percent.
The PIHeatingDemand attribute is 8 bits in length and specifies the level of heating demanded by the PI loop in percent.
The HVACSystemTypeConfiguration attribute specifies the HVAC system type controlled by the thermostat.
Local Temperature Calibration.
Occupied Cooling Setpoint attribute.
Occupied Heating Setpoint attribute.
Unoccupied Cooling Setpoint attribute.
Unoccupied Heating Setpoint attribute.
The MinHeatSetpointLimit attribute specifies the minimum level that the heating setpoint MAY be set to.
The MaxHeatSetpointLimit attribute specifies the maximum level that the heating setpoint MAY be set to.
The MinCoolSetpointLimit attribute specifies the minimum level that the cooling setpoint MAY be set to.
The MaxCoolSetpointLimit attribute specifies the maximum level that the cooling setpoint MAY be set to.
The MinSetpointDeadBand attribute specifies the minimum difference between the Heat Setpoint and the Cool SetPoint, in steps of 0.1C.
The RemoteSensing attribute is an 8-bit bitmap that specifies whether the local temperature, outdoor temperature and occupancy are being sensed by internal sensors or remote networked sensors.
Control Sequence Of Operation attribute.
The AlarmMask attribute specifies whether each of the alarms is enabled.
Thermostat Running Mode attribute.
NumberOfWeeklyTransitions attribute determines how many weekly schedule transitions the thermostat is capable of handling.
NumberOfDailyTransitions attribute determines how many daily schedule transitions the thermostat is capable of handling.
TemperatureSetpointHold specifies the temperature hold status on the thermostat.
TemperatureSetpointHoldDuration sets the period in minutes for which a setpoint hold is active.
The ThermostatProgrammingOperationMode attribute determines the operational state of the thermostats programming.
ThermostatRunningState represents the current relay state of the heat, cool, and fan relays.
The SetpointChangeSource attribute specifies the source of the current active OccupiedCoolingSetpoint or OccupiedHeatingSetpoint (i.e., who or what determined the current setpoint).
The SetpointChangeAmount attribute specifies the delta between the current active OccupiedCoolingSetpoint or OccupiedHeatingSetpoint and the previous active setpoint.
The SetpointChangeSourceTimestamp attribute specifies the time in UTC at which the SetpointChangeSourceAmount attribute change was recorded.
Specifies the degrees Celsius, in 0.1 degree increments, the Thermostat server will allow the LocalTemperature attribute to float above the OccupiedCooling setpoint or below the OccupiedHeating setpoint before initiating a state change to bring the temperature back to the users desired setpoint.
Specifies the minimum degrees Celsius, in 0.1 degree increments, the Thermostat server will allow the OccupiedSetback attribute to be configured by a user.
Specifies the maximum degrees Celsius, in 0.1 degree increments, the Thermostat server will allow the OccupiedSetback attribute to be configured by a user.
Specifies the degrees Celsius, in 0.1 degree increments, the Thermostat server will allow the LocalTemperature attribute to float above the UnoccupiedCooling setpoint or below the UnoccupiedHeating setpoint before initiating a state change to bring the temperature back to the users desired setpoint.
Specifies the minimum degrees Celsius, in 0.1 degree increments, the Thermostat server will allow the UnoccupiedSetback attribute to be configured by a user.
Specifies the maximum degrees Celsius, in 0.1 degree increments, the Thermostat server will allow the UnoccupiedSetback attribute to be configured by a user.
Specifies the delta, in 0.1 degrees Celsius, between LocalTemperature and the OccupiedHeatingSetpoint or UnoccupiedHeatingSetpoint attributes at which the Thermostat server will operate in emergency heat mode.
Indicates the type of Mini Split ACType of Mini Split AC is defined depending on how Cooling and Heating condition is achieved by Mini Split AC.
Indicates capacity of Mini Split AC in terms of the format defined by the ACCapacityFormat attribute.
Indicates type of refrigerant used within the Mini Split AC.
This indicates type of Compressor used within the Mini Split AC.
This indicates the type of errors encountered within the Mini Split AC.
AC Louver position attribute.
ACCoilTemperature represents the temperature in degrees Celsius, as measured locally or remotely (over the network).
This is the format for the ACCapacity attribute.