This attribute indicates a device s measurement capabilities.
The DCVoltage attribute represents the most recent DC voltage reading in Volts (V).
The DCVoltageMin attribute represents the lowest DC voltage value measured in Volts (V).
The DCVoltageMax attribute represents the highest DC voltage value measured in Volts (V).
The DCCurrent attribute represents the most recent DC current reading in Amps (A).
The DCCurrentMin attribute represents the lowest DC current value measured in Amps (A).
The DCCurrentMax attribute represents the highest DC current value measured in Amps (A).
The @e DCPower attribute represents the most recent DC power reading in @e Watts (W).
The DCPowerMin attribute represents the lowest DC power value measured in Watts (W).
The DCPowerMax attribute represents the highest DC power value measured in Watts (W).
The DCVoltageMultiplier provides a value to be multiplied against the DCVoltage, DCVoltageMin, and DCVoltageMax attributes.
The DCVoltageDivisor provides a value to be divided against the DCVoltage, DCVoltageMin, and DCVoltageMax attributes.
The DCCurrentMultiplier provides a value to be multiplied against the DCCurrent, DCCurrentMin, and DCCurrentMax attributes.
The DCCurrentDivisor provides a value to be divided against the DCCurrent, DCCurrentMin, and DCCurrentMax attributes.
The DCPowerMultiplier provides a value to be multiplied against the DCPower, DCPowerMin, and DCPowerMax attributes.
The DCPowerDivisor provides a value to be divided against the DCPower, DCPowerMin, and DCPowerMax attributes.
The ACFrequency attribute represents the most recent AC Frequency reading in Hertz (Hz).
The ACFrequencyMin attribute represents the lowest AC Frequency value measured in Hertz (Hz).
The ACFrequencyMax attribute represents the highest AC Frequency value measured in Hertz (Hz).
The NeutralCurrent attribute represents the AC neutral (Line-Out) current value at the moment in time the attribute is read, in Amps (A).
Active power represents the current demand of active power delivered or received at the premises, in @e kW.
Reactive power represents the current demand of reactive power delivered or received at the premises, in kVAr.
Represents the current demand of apparent power, in @e kVA.
Attribute represent the most recent 1st harmonic current reading in an AC frequency.
Attribute represent the most recent 3rd harmonic current reading in an AC frequency.
Attribute represent the most recent 5th harmonic current reading in an AC frequency.
Attribute represent the most recent 7th harmonic current reading in an AC frequency.
Attribute represent the most recent 9th harmonic current reading in an AC frequency.
Attribute represent the most recent 11th harmonic current reading in an AC frequency.
Attribute represent the most recent phase of the 1st harmonic current reading in an AC frequency.
Attribute represent the most recent phase of the 3rd harmonic current reading in an AC frequency.
Attribute represent the most recent phase of the 5th harmonic current reading in an AC frequency.
Attribute represent the most recent phase of the 7th harmonic current reading in an AC frequency.
Attribute represent the most recent phase of the 9th harmonic current reading in an AC frequency.
Attribute represent the most recent phase of the 11th harmonic current reading in an AC frequency.
Provides a value to be multiplied against the ACFrequency attribute.
Provides a value to be divided against the ACFrequency attribute.
Provides a value to be multiplied against a raw or uncompensated sensor count of power being measured by the metering device.
Provides a value to divide against the results of applying the @e Multiplier attribute against a raw or uncompensated sensor count of power being measured by the metering device.
Represents the unit value for the MeasuredNthHarmonicCurrent attribute in the format MeasuredNthHarmonicCurrent * 10 ^ HarmonicCurrentMultiplier amperes.
Represents the unit value for the MeasuredPhaseNthHarmonicCurrent attribute in the format MeasuredPhaseNthHarmonicCurrent * 10 ^ PhaseHarmonicCurrentMultiplier degrees.
Represents the single phase or Phase A, AC line current (Square root of active and reactive current) value at the moment in time the attribute is read, in @e Amps (A).
Represents the single phase or Phase A, AC active/resistive current value at the moment in time the attribute is read, in Amps (A).
Represents the single phase or Phase A, AC reactive current value at the moment in time the attribute is read, in Amps (A).
Represents the most recent RMS voltage reading in @e Volts (V).
Represents the lowest RMS voltage value measured in Volts (V).
Represents the highest RMS voltage value measured in Volts (V).
Represents the most recent RMS current reading in @e Amps (A).
Represents the lowest RMS current value measured in Amps (A).
Represents the highest RMS current value measured in Amps (A).
Represents the single phase or Phase A, current demand of active power delivered or received at the premises, in @e Watts (W).
Represents the lowest AC power value measured in Watts (W).
Represents the highest AC power value measured in Watts (W).
Represents the single phase or Phase A, current demand of reactive power delivered or received at the premises, in VAr.
Represents the single phase or Phase A, current demand of apparent (Square root of active and reactive power) power, in @e VA.
Contains the single phase or PhaseA, Power Factor ratio in 1/100th.
The Period in seconds that the RMS voltage is averaged over.
The number of times the average RMS voltage, has been above the AverageRMS OverVoltage threshold since last reset.
The number of times the average RMS voltage, has been below the AverageRMS underVoltage threshold since last reset.
The duration in seconds used to measure an extreme over voltage condition.
The duration in seconds used to measure an extreme under voltage condition.
The duration in seconds used to measure a voltage sag condition.
The duration in seconds used to measure a voltage swell condition.
Provides a value to be multiplied against the @e InstantaneousVoltage and RMSVoltage attributes.
Provides a value to be divided against the @e InstantaneousVoltage.
Provides a value to be multiplied against the @e InstantaneousCurrent and @e RMSCurrent attributes.
Provides a value to be divided against the @e ACCurrent, @e InstantaneousCurrent and @e RMSCurrent attributes.
Provides a value to be multiplied against the @e InstantaneousPower and @e ActivePower attributes.
Provides a value to be divided against the @e InstantaneousPower and @e ActivePower attributes.
Specifies which configurable alarms may be generated.
Specifies the alarm threshold, set by the manufacturer, for the maximum output voltage supported by device.
Specifies the alarm threshold, set by the manufacturer, for the maximum output current supported by device.
Specifies which configurable alarms may be generated.
Specifies the alarm threshold, set by the manufacturer, for the maximum output voltage supported by device.
Specifies the alarm threshold, set by the manufacturer, for the maximum output current supported by device.
Specifies the alarm threshold, set by the manufacturer, for the maximum output active power supported by device.
Specifies the alarm threshold, set by the manufacturer, for the maximum output reactive power supported by device.
The average RMS voltage above which an over voltage condition is reported.
The average RMS voltage below which an under voltage condition is reported.
The RMS voltage above which an extreme under voltage condition is reported.
The RMS voltage below which an extreme under voltage condition is reported.
The RMS voltage below which a sag condition is reported.
The RMS voltage above which a swell condition is reported.
Represents the Phase B, AC line current (Square root sum of active and reactive currents) value at the moment in time the attribute is read, in Amps (A).
Represents the Phase B, AC active/resistive current value at the moment in time.
Represents the Phase B, AC reactive current value at the moment in time the.
Represents the most recent RMS voltage reading in @e Volts (V).
Represents the lowest RMS voltage value measured in Volts (V).
Represents the highest RMS voltage value measured in Volts (V).
Represents the most recent RMS current reading in @e Amps (A).
Represents the lowest RMS current value measured in Amps (A).
Represents the highest RMS current value measured in Amps (A).
Represents the Phase B, current demand of active power delivered or received at the premises, in @e Watts (W).
Represents the lowest AC power value measured in Watts (W).
Represents the highest AC power value measured in Watts (W).
Represents the Phase B, current demand of reactive power delivered or received at the premises, in VAr.
Represents the Phase B, current demand of apparent (Square root of active and reactive power) power, in @e VA.
Contains the PhaseB, Power Factor ratio in 1/100th.
The number of times the average RMS voltage, has been above the @e AverageRMS @e OverVoltage threshold since last reset.
The number of times the average RMS voltage, has been above the AverageRMS OverVoltage threshold since last reset.
The number of times the average RMS voltage, has been below the AverageRMS underVoltage threshold since last reset.
The duration in seconds used to measure an extreme over voltage condition.
The duration in seconds used to measure an extreme under voltage condition.
The duration in seconds used to measure a voltage sag condition.
The duration in seconds used to measure a voltage swell condition.
Represents the Phase C, AC line current (Square root of active and reactive current) value at the moment in time the attribute is read, in Amps (A).
Represents the Phase C, AC active/resistive current value at the moment in time the attribute is read, in Amps (A).
Represents the Phase C, AC reactive current value at the moment in time the attribute is read, in Amps (A).
Represents the most recent RMS voltage reading in @e Volts (V).
Represents the lowest RMS voltage value measured in Volts (V).
Represents the highest RMS voltage value measured in Volts (V).
Represents the most recent RMS current reading in @e Amps (A).
Represents the lowest RMS current value measured in Amps (A).
Represents the highest RMS current value measured in Amps (A).
Represents the Phase C, current demand of active power delivered or received at the premises, in @e Watts (W).
Represents the lowest AC power value measured in Watts (W).
Represents the highest AC power value measured in Watts (W).
Represents the Phase C, current demand of reactive power delivered or received at the premises, in VAr.
Represents the Phase C, current demand of apparent (Square root of active and reactive power) power, in @e VA.
Contains the Phase C, Power Factor ratio in 1/100th.
The Period in seconds that the RMS voltage is averaged over.
The number of times the average RMS voltage, has been above the AverageRMS OverVoltage threshold since last reset.
The number of times the average RMS voltage, has been below the AverageRMS underVoltage threshold since last reset.
The duration in seconds used to measure an extreme over voltage condition.
The duration in seconds used to measure an extreme under voltage condition.
The duration in seconds used to measure a voltage sag condition.
The duration in seconds used to measure a voltage swell condition.